Part Number Hot Search : 
2SC57 BH7673 UGSP15D EXE8602 160808 15KPA78A FS020551 BYT53C
Product Description
Full Text Search
 

To Download P1224MCSP Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Audible/Visible
NotificAtioN
Selectable Output Strobe and Horn/Strobes
Models Available Strobes Red S1224MC S1224MCP S1224MCK S1224MCSP Horn/Strobes Red P1224MC P1224MCP P1224MCK P1224MCSP Horns Red H12/24 H12/24K Product Overview Operates on either 12V or 24V Widest range of candela options: 12V: 15 and 15/75 candela 24V: 15, 15/75, 30, 75, 110 candela Easy candela selection Lower current draw Easy DIP switch selection for horn options Easy mounting with QuickClickTM Synchronizable with MDL Sync*CircuitTM module Meets UL1971, NFPA72, and ADA signaling requirements
All strobe and horn/strobe models incorporate a new patented voltage booster design that has a more consistent flash bulb voltage over the range of candela selections. The benefit to the customer is a high quality strobe device.
White S1224MCW S1224MCPW
P1224MC Horn/Strobe
White P1224MCW P1224MCPW
White H12/24W
S1224MC Strobe
SpectrAlert(R) Selectable Output Horns, Strobes, and Horn/Strobes offer enhanced features that include the widest range of candela options available and the capability to recognize and self-adjust for either 12 or 24 volt operation. With an overall feature set that combines performance, installation ease, flexibility, and a consistent, aesthetically pleasing appearance, the SpectrAlert Selectable Output devices provide both the innovation and efficiency synonymous with the SpectrAlert name. Performance. SpectrAlert selectable output wall-mount horns, strobes, and horn/strobes offer key performance features long associated with the SpectrAlert name. The selectable candela strobes and horn/strobes offer average current draws that are not only lower than conventional fixed-candela SpectrAlert products, but also lower than similar selectable candela products. By consuming less current, the ability to connect even more devices per loop is possible, resulting in a lower installed cost. Installation. SpectrAlert selectable output horns, strobes, and horn/strobes offer the same installation-friendly features synonymous with the SpectrAlert name, such as the option of 2- and 4-wire operation; the ability to use standard size backboxes with no encroachment into the box; and universal mounting incorporating the labor-saving QuickClickTM feature. Such labor-savings features make wire connections simple and fast, further reducing installed cost. Flexibility. SpectrAlert selectable output strobes and horn/strobes offer the broadest range of candela options. In addition, the selectable output strobes and horn/strobes can operate on either 12V or 24V, with no setting required; the device recognizes and self-adjusts to the correct current automatically. Temporal 3 or Continuous tone options continue to be available, in either an Electromechanical or 3kHz pattern. Aesthetics. SpectrAlert selectable output horns, strobes, and horn/strobes incorporate the same stylish, low profile design of the conventional SpectrAlert products, for a consistent and aesthetically pleasing appearance across the entire product line.
7125-1209:222 7135-1209:223
S5512 S4011
3014150
122-02-E 126-02-E
Engineering Specifications General SpectrAlert horns, strobes and horn/strobes shall be capable of mounting to a standard 4 x 4 x 11/2 back box or a single gang 2 x 4 x 17/8 back box using the universal mounting plate included with each SpectrAlert product. Also, SpectrAlert products, when used in conjunction with the accessory Sync*Circuit Module, shall be powered from a non-coded power supply and shall operate on 12 or 24 volts. 12 volt rated devices shall have an operating voltage range of 9-17.5 volts. 24-volt rated devices shall have an operating voltage range or 17-33 volts. SpectrAlert products shall have an operating temperature of 32 to 120F and operate from a regulated DC or full wave rectified, unfiltered power supply. Strobe Strobe shall be a System Sensor SpectrAlert Model _______ listed to UL 1971 and be approved for fire protective service. The strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. Horn/Strobe Combination Horn/Strobe shall be a System Sensor SpectrAlert Model _______ listed to UL 1971 and UL 464 and shall be approved for fire protective service. Horn/strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible signaling appliances, flashing at 1Hz over the strobe's entire operating voltage range. The strobe light shall consist of a xenon flash tube and associated lens/reflector system. The horn shall have two tone options, two audibility options (at 24 volts) and the option to switch between a temporal 3 pattern and a non-temporal continuous pattern. Strobes shall be powered independently of the sounder with the removal of factory installed jumper wires. The horn on horn/ strobe models shall operate on a coded or non-coded power supply (the strobe must be powered continuously). Synchronization Module Module shall be a System Sensor Sync*Circuit _______ listed to UL 464 and shall be approved for fire protective service. The module shall synchronize SpectrAlert strobes at 1Hz and horns at temporal 3. Also, the module shall silence the horns on horn/ strobe models, while operating the strobes, over a single pair of wires. The module shall be capable of mounting to a 411/16 x 411/16 x 21/8 back box and shall control two Style Y (class B) or one Style Z (class A) circuit. Module shall be capable of multiple zone synchronization by daisy chaining multiple modules together and re-synchronizing each other along the chain. The module shall not operate on a coded power supply.
Specifications WalkTest SpectrAlerthorn/strobeandhornonly workon"walktests"withtimedurationsof4secondsorgreater InputTerminals 12to18AWG Dimensions Strobeandhorn/strobewithuniversal plate 5x5 5/8x2 15/16 Strobeandhorn/strobewithsmall footprintplate 3 3/8x5 5/8x2 5/16 Hornwithuniversalmountingplate 5x5 5/8x1 5/16 Hornwithoutmountingplate 2 15/16x5 5/16x1 5/16 Weight,hornonly 7.2oz. Weight,strobeandhorn/strobe 8.8oz. Mounting 4x4x1 1/2or2x4x1 7/8 standardboxes OperatingTemperature(Indoor) 32Fto120F(0Cto49C) Maximumhumidity(Indoor) 95%astestedperUL464 Outdoor(KSeries)OperatingTemperature -40Fto151F (-40Cto66C) Outdoorrating NEMA3R(perUL50) Voltages 12or24VDCandFWR1unfiltered Operatingvoltagerange 12V:8-17.5V;24V:16-33V Operatingvoltagerange(with Sync*Circuitmodule,MDL)2 12V:9-17.5V;24V:17-33V U.S.PatentNumbers 5,593,569 5,914,665 6,049,446
Notes: 1.FullWaveRectified(FWR)voltageisanon-regulated,time-var yingpowersourcethatisusedonsomepowersupplyandpaneloutputs. 2.TheMDLcausesaone-voltvoltagedropinthenotificationappliancecircuit.
Table 1-A: SpectrAlert Strobe UL Max. Current Draw
Candela Setting 15 15/75 30 75 110 FWR Operating Current-Strobe (mA RMS) 8-17.5V 16-33V 112 64 135 74 93 158 208 DC Operating Current-Strobe (mA RMS) 8-17.5V 16-33V 127 59 127 69 90 160 209
Explanation of Published Voltage, Current, and SPL Specifications
In May 2004 Underwriters Laboratories changed standard UL 1971 to require that operating current measuremments are made using RMS (root mean square) instead of peak or average values. RMS measurements more accurately predict the power consumption of a device since they take into account the entire current draw profile including surge, repetitive surge, and peak values. The published RMS current is the maximum operating current of that device within its operating voltage range. This current maximum may or Table 1-B: Horn UL Max. Current Draw Measurements (mA RMS) may not occur at the endpoints of the voltage range.
DC FWR 16-33V 23 33 53 57 37 32 49 56 8-17.5V 13 13 20 21 19 18 46 42 16-33V 23 23 44 40 29 33 49 58
Selectable Horn Tones
Temporal Low Volume High Volume NonTemporal Low Volume High Volume Electromechanical 3000HzInterrupted Electromechanical 3000HzInterrupted Electromechanical 3000HzInterrupted Electromechanical 3000HzInterrupted
8-17.5V 15 15 36 43 16 16 38 44
Similarly, UL tests the audibility of devices in accordance with UL 464 by measuring them across the operating voltage range to determine the minimum sound pressure level produced at any particular setting. During May 2004, UL also changed the way they list the voltage range of a device. All 12V products will be listed between 8 - 17.5V and all 24V products will be listed between 16 - 33V. Those devices are considered "regulated". Any product that does not operate within these ranges will be listed as a "special application" with its operating voltage specified on the device.
Notes
Table 1-C: 12VDC Horn/Strobe UL Max. Current Draw Measurements (mA RMS)
Temporal Low Volume Candela Setting 15 15/75 Electromechanical 111 127 3000 Hz 111 127 Non-Temporal 15 15/75 113 128 112 128 114 130 115 134 High Volume Electromechanical 112 126 3000 Hz 112 129
1. urrentdrawforstrobe-onlyproductsisshowninTable1-A. C 2. urrentdrawforhorn-onlyproductsisshowninTable1-B. C 3. 2VDC2-wirehorn/strobecurrentisshowninTable1-C. 1 4. 4VDC2-wirehorn/strobecurrentdrawisshowninTable 2 1-D. 5. urrentdrawforotherhorn/strobepowersuppliescanbe C calculatedbyaddingthestrobecurrentinTable1-Atothe horncurrentinTable1-Bfromthechosensettings.
Table 1-D: 24VDC Horn/Strobe UL Max. Current Draw Measurements (mA RMS)
Temporal Low Volume Candela Setting 15 15/75 30 75 110 Electromechanical 71 86 99 166 209 3000 Hz 70 85 98 166 209 Non-Temporal 15 15/75 30 75 110 74 86 101 167 213 74 88 101 167 213 79 93 107 173 218 82 96 110 176 222 High Volume Electromechanical 73 87 100 167 210 3000 Hz 75 88 100 170 213
SpectrAlert Strobe Candela Selections Forstrobecandelaselection,adjustslideswitchlocatedonthe rearoftheproductwhilewatchingtheviewingwindowonthe sideofthereflector.
Permissible Candela Settings
Candela Setting 15 15/75 30 75 Operating Voltage 12V OK OK 24V OK OK OK OK OK
Viewing Window
A0133-00
110
SpectrAlert Horn Sound Measurements (dBA)
Typical weatherproof mounting with universal plate
16-33V 75 75 80 81 79 79 84 86
Gasket Conduit Entrance WBB Plate #8-36 x 1/2 Flat Head Screw (4 total)
Selectable Horn Tones
Temporal Low Volume High Volume NonTemporal Low Volume High Volume Electromechanical 3000HzInterrupted Electromechanical 3000HzInterrupted Electromechanical 3000HzInterrupted Electromechanical 3000HzInterrupted
8-17.5V 67 68 71 72 71 72 76 77
DIP Switch Operation on P1224MC
OFF Low Temporal Electromech. ON Factory Default High Non-Temporal 3000Hz Base (rear)
A0110-00
Slot Paper Liner For Plate Gasket
Locking Rib
A0135-02
DIP Switch
SpectrAlert Ordering Information Model
P1224MC P1224MCW P1224MCP P1224MCPW P1224MCK P1224MCSP S1224MC S1224MCW S1224MCP S1224MCPW S1224MCK S1224MCSP
Description
SelectableOutputHorn/Strobe,12/24volt,red SelectableOutputHorn/Strobe,12/24volt,white SelectableOutputHorn/Strobe,12/24volt,red, plainhousing SelectableOutputHorn/Strobe,12/24volt, white,plainhousing SelectableOutputHorn/Strobe,12/24volt,red, outdoor SelectableOutputHorn/Strobe,12/24volt,red, "FUEGO"housing SelectableOutputStrobe,12/24volt,red SelectableOutputStrobe,12/24volt,white SelectableOutputStrobe,12/24volt,red,plain housing SelectableOutputStrobe,12/24volt,white, plainhousing SelectableOutputStrobe,12/24volt,red, outdoor SelectableOutputStrobe,12/24volt,red, "FUEGO"housing
Model H12/24 H12/24W H12/24K Accessories MDL MDLW MDLWA S-MP S-MPW BBS BBSW D-MP D-MPW WBB
Description Horn,12/24volt,red Horn,12/24volt,white Horn,12/24volt,red,outdoor Sync*CircuitModule,red Sync*CircuitModule,white Sync*CircuitModule,white,Canadianmodel SmallFootprintMountingPlate,red,forsinglegangbackbox SmallFootprintMountingPlate,white,forsinglegangbackbox Sur faceMountBackBoxSkir t,red Sur faceMountBackBoxSkir t,white UniversalMountingPlate(replacement),red UniversalMountingPlate(replacement),white WeatherproofBackBox
Notes
All of these SpectrAlert products are designed for wall mount only. All outdoor models must use weatherproof back box model WBB. Installation of less than 75 candela strobes may be permissible under the equivalent facilitation clause of the ADAAG (Sec. 2.2). However, it is the responsibility of the person or entity designing the fire alarm system to determine the acceptability of less than 75 candela strobes. All 15/75 candela strobes or horn/ strobes are recommended for 20 x 20 rooms or less.
System Sensor Sales and Service
System Sensor Headquarters 3825OhioAvenue St.Charles,IL60174 Ph:800/SENSOR2 Fx:630/377-6495 www.systemsensor.com System Sensor Canada Ph:905.812.0767 Fx:905.812.0771 System Sensor Europe Ph:44.1403.276500 Fx:44.1403.276501 System Sensor in China Ph:86.29.8832.0119 Fx:86.29.8832.5119 System Sensor in Singapore Ph:65.6273.2230 Fx:65.6273.2610 System Sensor - Far East Ph:85.22.191.9003 Fx:85.22.736.6580 System Sensor - Australia Ph:613.54.281.142 Fx:613.54.281.172 System Sensor - India Ph:91.124.237.1770x.2700 Fx:91.124.237.3118 System Sensor - Russia Ph:70.95.937.7982 Fx:70.95.937.7983
A05-0325-006*9/05*#1526
(c) 2005SystemSensor.Thecompanyreservestherighttochangeproductspecificationswithoutnotice.


▲Up To Search▲   

 
Price & Availability of P1224MCSP

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X